EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
CIT-10 conduction sensitivity test system
Brand:
FRANKONIA
- Product Description
- Main features
- Technical parameters
-
- Commodity name: CIT-10 conduction sensitivity test system
- Commodity ID: 1064492893520678912
- 品牌11: FRANKONIA
- 行业: 民用
- 描述: CIT-10 is a complete conducted radio frequency susceptibility test system, according to the standards IEC/EN 61000-4-6, GB/T 17626.6, ISO 11452-4, MIL-STD 461 CS114, SAE-J1113-2, DC 10614 and similar standard. Its internal RF signal source and power ampli
- 品牌: FRANKONIA
CIT-10 is a complete conducted radio frequency susceptibility test system, according to the standards IEC/EN 61000-4-6, GB/T 17626.6, ISO 11452-4, MIL-STD 461 CS114, SAE-J1113-2, DC 10614 and similar standard. Its internal RF signal source and power amplifier can output a maximum power of 150W in the frequency range of 100 (10)kHz to 400 MHz. The resulting signal is measured with one of the internal RF voltmeters (up to 3). Additionally, forward and reflected power can be measured through an optional internal directional coupler. The entire test system allows fully automatic testing of the specified frequency range. The CIT-10 is convincingly easy to operate and excellent price/performance ratio as a "stand-alone" test system, and can also be used in conjunction with other coupling and decoupling networks.
-
main feature:
Satisfy IEC/EN 61000-4-6, GB/T 17626.6 Radio Frequency Field Induced Conducted Disturbance Immunity and ISO 11452-4, MIL-STD 461 CS114 BCI Test
Signal source, RF power amplifier, RF power meter and directional coupler (option) are integrated in a 19-inch case
Can be operated independently by computer
Comes with control software
The most important parameters can be displayed via software on the integrated display
EUT status can be detected automatically
Can be controlled via USB port
Compatible with a full range of CDN products
-
Specific indicators:
RF Voltmeter Frequency Range 10KHz-400MHz Measuring range -40dBm-+30dBm precision ±0.5dB VSWR <1.1:1 enter BNC,50Ω RF signal generator output Measuring range Frequency Range 10KHz-400MHz frequency resolution 1Hz Output level range -63dBm-0dBm Output level resolution 0.1dB Output level accuracy ±0.5dB (maximum ±1dB) Accuracy (frequency) ±5ppm(TCX0) harmonic <-30 dBc AM (internal) 0-100%, resolution 1% (internal AF signal source) AM (external) BNC 1Hz-100KHz0-100%, input impedance>100kΩ pulse modulation Duty cycle 5-95%, resolution 1% VSWR <1.5:1 RF power amplifier Frequency Range power gain distortion 10KHz-250MHz 75W 51dB±1.5dB <-20dBc @ 50W 100KHz-400MHz 75W 51dB±1.5dB <-20dBc @ 50W 100KHz-250MHz 25W 46dB±1.5dB <-20dBc @ 20W input resistance 50Ω,VSWR<1.5:1 output impedance 50Ω A F signal source output port BNC Frequency Range 1Hz-100KHz frequency resolution 0.1Hz The output voltage 0-1V; resolution 5mV Accuracy (frequency) ±50ppm Signal Sine/Square/Triangle E UT - Fail input input resistance 2.2kΩ level Compatible with TTL/CMOS, fiber decoupling E UT - monitor input Input voltage 0-10V input resistance 100 kΩ Amplifier monitoring output BNC,50Ω level -40dB (power amplifier output), ±3dB RF voltmeter (internal, 2 pcs) Frequency Range 10KHz-400MHz Measuring range 0dBm-+53dBm precision ±0.5dB Directional coupler (option) Frequency Range 10KHz-400MHz power 200W CW Insertion loss 0.5dB max VSWR 1.25:1 max directionality 20dB minimum Interface Type USB-A Multimeter (for EUT control) USB-A Relay switch unit USB-B connect computer Packing List CIT-10 host, cable, system software General parameters temperature range 0-40℃ Preheat time 15 minutes Chassis shell 19" cabinet or desktop Dimensions (WxHxD) 449mm x 133mm x 435.5mm AC power 100-240Vac;50/60Hz Model Description CIT-10/25 integrated 25W RF power amplifier CIT-10/75 integrated 75W RF power amplifier CIT-10/75 MIL Integrated 75W RF Power Amplifier CIT-10/75 W does not include RF power amplifier