EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
NSG4070C1 RF Conducted Immunity Testing System
Brand:
TESEQ
- Product Description
- Main features
- Technical parameters
-
- Commodity name: NSG4070C1 RF Conducted Immunity Testing System
- Commodity ID: 1064825767830638592
- 品牌11: TESEQ
- 行业: 民用
- 描述: NSG 4070C1 is a multifunctional device that can perform EMC immunity and compliance testing according to IEC/EN 61000-4-6 and some automotive BCI standards.
- 品牌: TESEQ
The NSG 4070C1 is a multifunctional device for EMC immunity testing and compliance testing according to IEC/EN 61000-4-6 and some automotive BCI standards. The NSG 4070C1's modular setup allows the use of internal or external amplifiers to suit a wide variety of applications. Powerful and easy-to-use firmware makes the NSG 4070 independent of external PC and control software, but it can also control system operation remotely.
-
Recommended applications (by standard):
ISO/DTS 7637-4: 1, 2, 5, 10MHz; NSG4070C1-80 is recommended
IEC 61000-4-20: 0.03GHz~1GHz; NSG4070C1-45 is recommended
ISO 11452-4 and other BCI standards: 10kHz~400MHz; NSG4070C1-110 is recommended
MIL-STD-461G CS114: 4kHz~200MHz; recommended to use NSG4070C1-60, NSG4070C1-110
Namur and IEC/EN 61326-3-2: 10kHz~80MHz; NSG4070C1-60 is recommended
IEC/EN 61000-4-6: 150kHz~80(230)MHz; recommended to use NSG4070C1-35, NSG4070C1-80
-
model
NSG4070C-35
NSG4070C-45
NSG4070C-60
NSG4070C-80
NSG4070C-110
Signal generator
Frequency Range
4 kHz~1GHz
resolution
1 Hz
reference frequency
10 MHz
Level range
-60 dBm~+10 dBm
resolution
0.1 dB
set time
10 ms
AM Depth
0 ~ 100%
AM Frequency Range
1 Hz ~50 kHz
frequency resolution
1 Hz
Pulse modulation rise/fall time
<1 us
Pulse modulation frequency range
0.01 Hz~1 MHz
frequency resolution
0.01 Hz
duty cycle
0.1%~100%
External Modulation Delay Time
< 1 μs / 180°
cycle
Minimum 20 us
Pulse Width
Minimum 10us
dynamometer
Frequency Range
4 kHz~1 GHz
Measuring range
Channel 1: -35dBm~+27dBm (NSG 4070C1-60 and NSG 4070C1-110: -40dBm~+27dBm)
Channel 2, 3: -45dBm~+20 dBm
Maximum input
+28dBm
Noise floor
>5dB(below measuring range)
Input reflection loss
>20 dB(less than 500 MHz)
>17 dB(500 MHz~1 GHz)
connector
BNC,50Ω
precision
<0.5 dB, typical. <0.3 dB
Power amplifier
Output power
35W
45W
60W
80W
110W
Frequency Range
150kHz~230MHz
9kHz~1GHz
10kHz(4kHz)~400MHz
150kHz~230MHz
10kHz(4kHz)~400MHz
type
single band,
Class A
single band,
Class A
single band,
Class A
single band,
Class A
single band,
Class A
Impedance (input/output)
50Oh
50Oh
50Oh
50Oh
50Oh
Input reflection loss (min.)
10 dB
10 dB
10 dB
10 dB
10 dB
Output reflection loss (lossless)
0 dB
0 dB
0 dB
0 dB
0 dB
Gain (min)
48 dB
49 dB
45dB ,4k~10kHz;
50dB,10k~400MHz
50 dB
47dB ,4k~10kHz;
50dB,10k~400MHz
Gain flatness
±3 dB
±3 dB
±3 dB
±3 dB
±3 dB
Saturated output power (min)
44.9dBm
46.0dBm,<400MHz;
44.3dBm,>400MHz;
42dBm,4k ~10kHz;
48.5dBm,10k~400MHz
48.5dBm
43dBm,4k ~10kHz;
49.9dBm,10k~400MHz
Linear output power (min)
43.5dBm
44.9dBm,<400MHz;
41.9dBm,>400MHz;
40dBm,4k ~10kHz;
47.5dBm,10k~400MHz
47.5dBm
41dBm,4k ~10kHz;
48.5dBm,10k~400MHz
Input power (max.)
+10 dBm
+10 dBm
+10 dBm
+10 dBm
+10 dBm
Harmonic distortion (typical)
< -17 dBc
< -20 dBc
< -18 dBc
< -20 dBc
< -20 dBc
Power supply
power consumption
About 415W; 100~240VAC, 50/60Hz;
Amplifier approx. 80W;
The amplifier is about < 1kW,
100~240VAC,50/60Hz;
general
Working stability range
0 °C~40 °C
Storage temperature range
-20 °C~60 °C
relative humidity
95%, 30°C (no hydrous condensation)
Mechanical specifications
Dimensions (W×H×D)
450 ×150×423mm
650 ×460×600mm
weight
Approx. 15kg (with built-in amplifier)
Approx. 8kg (without built-in amplifier)
Approx. 44kg