-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
-
-
-
-
EMC Test System For Civil Products
-
- Electrostatic Discharge Immunity
- Radiated, radio-frequency,electromagnetic field immunity
- Electrical Fast Transient Burst Immunity
- Surge immunity
- Immunity To Conducted Disturbance Induced by Radio Frequency Field
- Power Frequency Magnetic Field Immunity
- Voltage dips, short interruptions and voltage variations immunity
- Harmonics and interharmonics including mains signalling at AC power port, low frequency immunity
- Voltage Fluctuation Immunity Test
- Common mode disturbances in the frequency range 0 Hz to 150 kHz Immunity
- Ripple on DC input power port immunity
- Three-phase Voltage Unbalance Immunity Test
- Power Frequency Variation Immunity Test
- Oscillatory Wave Immunity Test
- Damped Oscillatory Magnetic Field Immunity Test
- Differential mode disturbances immunity test
- DC power input port voltage dip, short interruption and voltage variations test
-
Automotive Electronic EMC Test System
-
- Electrostatic Discharge Immunity
- Electrical Transient Conducted Immunity
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Anechoic Chamber Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Transverse Wave (TEM) Cell Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-large Current injection (BCI) method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Stripline Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-direct Injection Of Radio Frequency (RF) Power
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Magnetic Field Immunity Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Portable Transmitter Simulation Method
- Immunity Test To Narrowband Radiated Electromagnetic Energy-Conduction Immunity Method For Extended Audio Range
- High Voltage Electrical Performance ISO 21498-2 Test System
- High Voltage Transient Conducted Immunity (ISO 7637-4)
-
-
- CE101(25Hz ~ 10kHz power line conduction emission)
- CE102(10kHz ~ 10MHz power line conduction emission)
- CE106(10kHz ~ 40GHz antenna port conducted emission)
- CE107 (Power Line Spike (Time Domain) Conducted Emission)
- RE101(25Hz ~ 100kHz magnetic field radiation emission)
- RE102(10kHz ~ 18GHz electric field radiation emission)
- RE103(10kHz ~ 40GHz antenna harmonic and spurious output radiated emission)
-
- CS101(25Hz ~ 150kHz power line conduction sensitivity)
- CS102(25Hz ~ 50kHz ground wire conduction sensitivity)
- CS103(15kHz ~ 10GHz Antenna Port Intermodulation Conducted Sensitivity)
- CS104(25Hz ~ 20GHz antenna port unwanted signal suppression conduction sensitivity)
- CS105(25Hz ~ 20GHz antenna port intermodulation conduction sensitivity)
- CS106 (Power Line Spike Signal Conduction Sensitivity)
- CS109(50Hz ~ 100kHz shell current conduction sensitivity)
- CS112 (Electrostatic Discharge Sensitivity)
- CS114(4kHz ~ 400MHz cable bundle injection conduction sensitivity)
- CS115 (Conduction sensitivity of cable bundle injection pulse excitation)
- CS116(10kHz to 100MHz Cable and Power Line Damped Sinusoidal Transient Conduction Sensitivity)
- RS101(25Hz ~ 100kHz magnetic field radiation sensitivity)
- RS103(10kHz ~ 40GHz electric field radiation sensitivity)
- RS105 (Transient Electromagnetic Field Radiated Susceptibility)
-
-
-
-
-
-
Product
EMC Testing Solution Provider
CDN M1/2/3/4/5 Used for coupling and decoupling networks of power cords
Brand:
FRANKONIA
- Product Description
- Main features
- Technical parameters
-
- Commodity name: CDN M1/2/3/4/5 Used for coupling and decoupling networks of power cords
- Commodity ID: 1064492122444025856
- 品牌11: FRANKONIA
- 行业: 民用
- 描述: The CDN-M coupling/decoupling network is used for the anti-interference test of the power line required in the conduction immunity of IEC61000-4-6/GB/T 17626.6 standard radio frequency field induction. Various types of CDN are available for EUT testing wi
- 品牌: FRANKONIA
Coupling and decoupling network meeting IEC61000-4-6 standard
The CDN-M coupling/decoupling network is used for the anti-interference test of the power line required in the conduction immunity of IEC61000-4-6/GB/T 17626.6 standard radio frequency field induction. Various types of CDN are available for EUT testing with a maximum voltage of 1000 Vac and a current of 100 A.

Unshielded power cord CDN-M3 circuit diagram
-
-
Specific indicators:
model
CDN-M1/2/3/4/5
C DN-M1/2/3/4/5/-HV
CDN-M2/3/4/5/
-63A/100ARF-IN
Frequency Range
(10kHz)150kHz-80MHz/230MHz(300MHz)
power input
6W (continuous)
Decoupling parameters
(RF In-AE)>30dB:
(150kHz-80MHz)
10dB+5dB:
(80MHz-230MHz)>30dB:
(150kHz-80MHz)
>15dB:
(80MHz-230MHz)>30dB:
(150kHz-80MHz)
>15dB:
(80MHz-230MHz)Insertion loss
(RF In-EUT)10dB+2/-1dB:
(150kHz-80MHz)
10dB+5dB:
(80MHz-230MHz)10dB+2/-1dB:
(150kHz-80MHz)
10dB+5dB:
(80MHz-230MHz)10dB+2/-1dB:
(150kHz-80MHz)
10dB+5dB:
(80MHz-230MHz)Connector
BNC
UT/ YES
Maximum input voltage
AC(Line-PE)280V
600V
(1000V VHV-models)600V
Maximum input voltage
AC(Line-Line)485V
1000V
(1700V VHV-models)1000V
Maximum input voltage
DC500V
1000V
6000V
Current class
(AE-EUT)16A/32A/63A/100A;(M1/M2+3 IPE<0.5A)
Insertion loss (AE-EUT)
<1 dB(DC-100KHz)
Connector
4mm banana safety terminal, current > 32A is 6mm round plug, including safety test line
physical dimension
width x height x length
160mmx84.5mmx240mm
200mmx122.5mmx400mm
200mmx122.5mmx400mm
Ordering Information:
CDN-M1, 4mm banana terminal, 150KHz-230MHz
CDN-M1-10k, 4mm banana terminal, 10KHz-230MHz
CDN-L1, 4mm banana terminal, 150KHz-230MHz
CDN-M2-10k, 4mm banana terminal, 10KHz-230MHz
CDN-M2, 4mm banana terminal, 150KHz-300MHz
CDN-M2-32A, 4mm banana terminal, 150KHz-230MHz
CDN-M2-32A-HV, 4mm banana terminal, 150KHz-230MHz
CDN-M2-63A-HV, 6mm banana terminal, 150KHz-80MHz
CDN-M2-100A-HV, 6mm round terminal, 150KHz-80MHz
CDN-M2+3,4mm banana terminal, 150KHz-300MHz
CDN-M2+M3-10k, 4mm banana terminal, 10KHz-300MHz
CDN-M2+3-32A, 4mm banana terminal, 150KHz-230MHz
CDN-M3-10k, 4mm banana terminal, 150KHz-300MHz
CDN-M3-L, L1/L2/L3, 4mm banana terminal, 150KHz-230MHz
CDN-M3-32A, 4mm banana terminal, 150KHz-230MHz
CDN-M3-L1L2N-32A, L1/L2/N, 4mm banana terminal, 150KHz-230MHz
CDN-M3-L-32A, L1, L2, L3, 4mm banana terminal, 150KHz-230MHz
CDN-M3-L-32A-10k, L1/L2/L3, 4mm banana terminal, 10KHz-230MHz
CDN-M3-32A-HV,,4mm banana terminal, 150KHz-80MHz
CDN-M3-L-32A-HV, 4mm banana terminal, 150KHz-80MHz
CDN-M4-32A-10k, 4mm banana terminal, 10KHz-230MHz
CDN-M4-32A-HV, 4mm banana terminal, 150KHz-80MHz
Calibration Adapter, CDN-M1/-M2/-M3
CDN-M4-N-32A-HV, 4mm banana terminal, 150KHz-80MHz
CDN-M4-63A-HV, 6mm round terminal, 150KHz-80MHz
CDN-M4-N-63A-HV, L1/L2/L3/N, 6mm round terminal, 150KHz-80MHz
CDN-M4-100A-HV, 6mm round terminal, 150KHz-80MHz
CDN-M4-N-100A-HV, L1/L2/L3/N, 6mm round terminal, 150KHz-80MHz
CDN-M5, 4mm banana terminal, 150KHz-230MHz
CDN-M5-L-32A, 4mm banana terminal, 150KHz-230MHz
CDN-M5-32A-HV, 4mm banana terminal, 150KHz-80MHz
CDN-M5-32A-VHV, 4mm banana terminal, 150KHz-80MHz
CDN-M5-63A-HV, 6mm banana terminal, 150KHz-80MHz
CDN-M5-L-100A-VHV, 6mm banana terminal, 150KHz-80MHz
Calibration Adapter, CDN-M4/-M5
Calibration adapter "△", CDN-M4/-M5
Calibration Adapter, CDN-M4-63A/-M5-63A
Calibration Adapter, CDN-M4-100A/-M5-100A
Mounting bracket for calibration adapter including 50/150Ω adapter and 50Ω termination