    • Commodity name: MDS-21 absorption clamp
    • Commodity ID: 1064832921455185920
    • 品牌11: ROHDE&SCHWARZ
    • 描述: The MDS-21C Absorption Clamp meets the requirements of CISPR 16-1-3/EN 55016-1-3 for interference power measurements in the frequency range of 30 MHz to 1000 MHz and is suitable for shielding effectiveness measurements.
    • 品牌: ROHDE&SCHWARZ

    The MDS-21C Absorption Clamp meets the requirements of CISPR 16-1-3/EN 55016-1-3 for interference power measurements in the frequency range of 30 MHz to 1000 MHz and is suitable for shielding effectiveness measurements.

    Interference emitted by appliances, machines and systems must comply with the limits set by national and international standards. Interference power on cables is measured using MDS absorption clamps and EMI measurement receivers according to CISPR 13/EN 55013, CISPR 14-1/EN 55014-1 and EN 50083-2. They can also be used with dual-port measurement devices to measure the shielding effectiveness of cables in accordance with IEC 62153-4 and EN 50083-2.

    The MDS absorption clips are also used to test the efficiency of interference suppression devices for high-voltage ignition systems in accordance with CISPR 12/EN 55012.

    In the frequency range below 30 MHz, interference as defined by many standards is defined by measuring the interference voltage generated by the tested device at the termination of the line impedance stabilization network. This is important because interference in this frequency range propagates primarily through the cable.

    Above 30 MHz, radiated interference dominates, and interference is defined by the interference field strength at a certain distance. Smaller tested devices emit interference mainly through connected cables (e.g. power cables). For this reason, in order to reduce the extensive field strength measurements to a minimum, many standards provide for MDS absorption clamp to measure the interference power.

  • Frequency range from 30MHz to 1000MHz

    Maximum cable diameter: 20 mm

    Clamp opens for easy insertion of test cables

    Continuous ball bearing rollers for automatic measurement

    Meets the requirements and calibration of CISPR 16-1-3

  • Frequency Range

     

    30MHz-1000MHz

    Insertion loss

    Conforms to CISPR 16-1-3

    17 dB (nom.)

    Coupling factor DF

    Conforms to CISPR 16-1-3

    > 21dB

    decoupling factor DR

    Conforms to CISPR 16-1-3

    > 30dB

    Receiver input impedance

     

    50Ω

    Maximum allowable DC current or peak AC current

     

    30A

    The maximum tolerable RF input power

     

    20W

    cable diameter

     

    20 mm

    Connector

    RF output/input

    Power Disturbance/Immunity Measurements

    N female, 50Ω

    General data

    External dimensions

    W × H × D

    645 x 66 (110) x 102 mm

    weight

     

    5.8 kg