CA EFT kit Load Resistor Assembly for Electrical Fast Transient Pulse Group Calibration

Brand:

EM TEST

CA EFT kit Load Resistor Assembly for Electrical Fast Transient Pulse Group Calibration
  • Product Description
  • Main features
  • Technical parameters
    • Commodity name: CA EFT kit Load Resistor Assembly for Electrical Fast Transient Pulse Group Calibration
    • Commodity ID: 1064481961155383296
    • 品牌11: EMTEST
    • 行业: 民用
    • 描述: The CA EFT kit contains the required load resistors and a set of adapters to connect the coaxial matching resistors to the output ports of the test device.
    • 品牌: EM TEST

    The pulse waveforms generated by an electrical fast transient/pulse group generator designed according to IEC 61000-4-4 need to be verified at 50 ohm and 1000 ohm loads at the 50 ohm coaxial high voltage output; and also at 50 ohm loads at the output of the test device connected by the coupling network during power line testing.

    The CA EFT kit includes the required load resistors and a set of adapters to connect the coaxial matching resistors to the output ports of the test device.

    Translated with www.DeepL.com/Translator (free version)


  • ● Calibration kit according to IEC 61000-4-4

    ● At the same time meet the relevant requirements of ISO 7637, Annex D standards

    ● Contains a 50 ohm load resistor

    ● Includes a 1000 ohm load resistor

    ● Adapter included to connect the load resistor to the output of the coupling network for easy measurement

    Standards compliant:

    ● EN 61000-4-4

    ● IEC 61000-4-4

    ● ISO 7637-1:1990

    ● ISO 7637-2:1990

    ● ISO 7637-2:2004

    ● ISO 7637-2:2011

    ● ISO 7637-3:1995

    ● ISO 7637-3:2007

    application:

    ● Measurement example using KW 50

    ☆ Set the open circuit voltage of the EFT/burst generator (50 ohm output): 2,000 V

    ☆ The resulting output voltage across a 50 ohm matching resistor is: 1,000 V

    ☆ Measuring voltage Vm: 10 V

    ☆ Under 50 ohm input impedance, the voltage value measured by the oscilloscope: 5 V

    ☆ Generated attenuation value (theoretical): 400:1

     

    EMTEST

    ● Measurement example using KW 1000

    ☆ Set the open circuit voltage of the EFT generator (50 ohm output) to: 2,000 V

    ☆ The resulting output voltage across a 1,000 ohm matching resistor is: 1,905 V

    ☆ Measuring voltage Vm: 4 V

    ☆ Under 50 ohm input impedance, the voltage value measured by the oscilloscope: 2 V

    ☆ Generated attenuation value (theoretical): 1,000:1

     

    EMTEST

  • Specific indicators:

    KW 50, 50 OHM load resistor for EFT/Burst transient testing only
    Input voltage up to 8,000 V
    input resistance 50 ohms +/-2%
    output impedance 50 ohms
    Partition ratio 100:1
    size 155mm x 26mm x 26mm
    weight about 150g
      In a 50 ohm system the divider ratio is n=400
    KW 1000, 1000 OHM load resistance for EFT/Burst transient testing only
    Input voltage up to 8,000 V
    input resistance 1000 ohms +/-2%
    output impedance 50 ohms
    Partition ratio 500:1
    size 155mm x 26mm x 26mm
    weight about 150g
      The divider ratio in a 50 ohm system is n=1000
    AD-CA EFT Adapter
    Function 4 mm / 6 mm adapter for F103 coaxial connector (matches coupling network to load resistance)
    option
    ADA-800 SHV-F103 Adapter for matching KW 50 and KW 1000 load resistors to the coaxial high voltage output of EFT 800 and EFT 500M/N8
    CA HFK kit Capacitive coupling clamp calibration adapter kit, consisting of
    - sensor board: conforming to IEC / EN 61000-4-4 standard Ed 3.0
    - support accessory: fixes the KW 50 adapter at the same
    100 mm height as the capacitive coupling clamp